    HKel Electrical Appliances (Shanghai) Co., Ltd. is a professional low-voltage electrical appliances OEM licensing production and sales as one of the enterprises. Hangkai Professional Molded Case Circuit Breaker Manufacturer, mainly produces HKM1 Molded Case Circuit Breaker, HKM3 Molded Case Circuit Breaker, providing product maintenance, type selection, knowledge and other services. Tel: 021-57161889

    More
  • Products
    • miniature circuit breaker
    • MCCB Series
    • Air-operated Circuit Breaker
    • Dual Power Switch
    • Double power source auto-switch
    • Isolating Dual power switch
    • Control and Protective Switching Devices
    • Multi function power meter
    • intelligent control device
    • intelligent composite switch
    • dc operation power supply
    • temperature and humidity controller
    • knife switch series
    P
    Home>News>MCCB Knowledge>Terminological Interpretation of TT, TN and IT Systems for Molded Case Circuit Breakers
    • MCCB Knowledge
    • MCCB Model Selection
    • MCCB Maintain
    • Product Knowledge
    • Industry Dynamics

    Terminological Interpretation of TT, TN and IT Systems for Molded Case Circuit Breakers

    Author : HKel Electrical Appliances (Shanghai) Co., Ltd. Release Time : 2018-12-10 14:35:00 View Times:

    Terminological Interpretation of TT, TN and IT Systems for Molded Case Circuit Breakers:

    TT is a protective grounding system, that is, the protective system of direct grounding of metal shell of electrical equipment.

    TN is a zero-connection protection system, that is, the metal shell of electrical equipment is directly connected with the zero-line protection system, which can be divided into TN-c and TN-s.

    IT means that there is no grounding or high resistance grounding on the power side and grounding protection on the load side.

    Application of TT, TN and IT systems for plastic case circuit breakers:

    1. TT can be grounded directly by three-wire and three-phase ground wire. When a leakage fault occurs in a TT system, the fault voltage of the metal shell of the equipment is large, but the current is small, which is not conducive to the action of the protective switch and harmful to people and equipment. In domestic, it is limited to the occasion of electronic equipment with high local grounding requirements. At present, this system is not generally used in the construction site.

    2. The commonly used system is TN system, i.e. three-phase four-wire system. The zero line of this system, i.e. the neutral line, is not allowed to be disconnected. This system can be further divided into TN-c, three-phase four-wire system, three-wire plus neutral line and TN-S three-wire plus ground line (both neutral line and ground line are shared) which are currently supplied by a single transformer or whose substations are relatively close to the construction site. The TN-S system is basically adopted in the construction foundation, which cooperates with the step-by-step leakage protection, and indeed plays a role in ensuring the safety of construction power consumption.

    Note:

    When using TN system, it is not allowed to disconnect the protective zero line.

    3. There is also TN-C-S three-phase five-wire system, that is, three fire lines plus one neutral line and one ground line. TN-C-S system improves the safety of operators and equipment. TN-C-S system is usually adopted in construction site when the platform is far away from the site or there is no special transformer for construction.

    Note:

    1. TT system should be used in 10KV and 35KV high-voltage systems and some low-voltage power supply systems in mines and underground mines. It is not suitable for application in construction site.

    2. TN-C is composed of three fire lines plus ground lines, and the neutral line and ground line are combined into one line. TN-S is composed of three fire lines plus neutral lines, which are separated from ground lines.


    Next Page:How to check the contact quality of plastic case circuit breaker? Previous Page:The structure of common plastic case circuit breaker and the function of its important components are explained in detail.
    Return

    Hot News: MCCB Service MCCB Selection And Installation MCCB Development MCCB lectotype

    HKel Product
    miniature circuit breaker MCCB Series Air-operated Circuit Breaker Dual Power Switch Double power source auto-switch Isolating Dual power switch Control and Protective Switching Devices Multi function power meter intelligent control device intelligent composite switch dc operation power supply temperature and humidity controller knife switch series
    News
    MCCB Knowledge MCCB Model Selection MCCB Maintain Product Knowledge Industry Dynamics
    Service
    Service Idea Marketing Network
    About Us
    Company Profile Address by the Chair Honor Corporate Culture
    Contant Us
    Contact Us Message
    021-57161889

    77785811@qq.com
    1664 shanghai-hangzhou highway, nanqiao town, fengxian district, ShangHai

    Pay Attention To Us
    Contact UsAbout Us

    copyright_2017 HKel Electrical Appliances (Shanghai) Co., Ltd. all rights reserved